NOARK – SH-5 DC – T1/T2 – IP65
Product details
| Manufacturer | |
|---|---|
| Weight | 0,085 kg |
SH-5 DC
SH-5 DC is a modular DC surge protection device for protecting photovoltaic strings. It features a T1/T2 type surge protector and an MC4 Stäubli panel connector. The IP65-rated enclosure, UV resistance, and plug-and-play readiness facilitate the module’s installation in the system.
Key advantages of SH-5 DC
- DC surge protector type T1/T2 Phoenix/VAL-MS-T1/T21000DC-PV/2+V
- IP65 enclosure protection rating and IK08 mechanical resistance
- Rated insulation voltage 400 V AC and 1500 V DC
- Maximum discharge current Imax of 40 kA and response time tA ≤ 25 ns
- One PV string input and one string output, plus MC4 Stäubli panel connector
- UV resistance, operating temperature range from −25°C to +60°C, and a 5-year warranty period
Who is this a good choice for?
SH-5 DC is intended for users of photovoltaic installations in households and businesses who need DC side protection using a T1/T2 surge arrester. IP65 rating, MC4 Stäubli connection, and readiness for connection support the use of the module in installations with a single PV string.
| Parameter | Value |
|---|---|
| General information | |
| Construction | Modular |
| Protection degree (IP) | IP65 |
| Warranty period (years) | 5 |
| UV resistance | Yes |
| Ready to connect | Yes |
| Weight (kg) | 1,040 |
| Rated AC voltage (V) | 400 |
| Rated DC voltage (V) | 1500 |
| Conformity marking | CE |
| Basic DC side parameters | |
| Number of PV string inputs (pcs.) | 1 |
| Number of PV string outputs (pcs.) | 1 |
| Number of DC surge arresters (pcs.) | 1 |
| DC surge arrester type | Phoenix T1/T2 |
| Connector type | Panel-mounted MC4 Stäubli |
| Enclosure parameters | |
| Housing model | PHS 4 T |
| Number of fields (pcs.) | 4 |
| Dimensions of the enclosure without cable glands and MC4 connectors — length (mm) | 120,00 |
| Dimensions of the enclosure without cable glands and MC4 connectors — width (mm) | 128,00 |
| Dimensions of the enclosure without cable glands and MC4 connectors — height (mm) | 201,00 |
| Compliance with standards | EN 60670-1, EN 62208 |
| Degree of enclosure protection (IP) | IP65 |
| Protection class | II |
| Rated insulation voltage Ui (V) | 400 V AC, 1500 V DC |
| Wire glow test temperature (°C) | 650°C |
| Impact resistance (IK) | IK08 |
| UV resistance | Yes |
| Housing material | Halogen-free, Recyclable plastic |
| Operating temperature (°C) | -25°C – +60°C |
| DC surge protector (SPD) | |
| Device parameters | |
| Manufacturer / model | PHOENIX/VAL-MS-T1/T21000DC-PV/2+V |
| Overvoltage protection class | T1 / T2 |
| Open-circuit voltage UOCSTC (V DC) | ≤ 975 V DC |
| Maximum discharge current Imax (kA, 8/20 µs) | 40 kA |
| Response time tA (ns) | ≤ 25 ns |
| Charge during lightning impulse test (As, 10/350 µs) | 2.5 A |
| Specific energy of impulse current (kJ/Ω, 10/350 µs) | 6.25 kJ/Ω |
| Peak impulse current Iimp (kA, 10/350 µs) | 5 kA |
| Total discharge current Itotal (kA, 8/20 µs) | 40 kA |
| Total discharge current Itotal (kA, 10/350 µs) | 5 kA |
| Insulation resistance Riso (GΩ) | > 5 GΩ (at 500 V DC) |
| Rated discharge current In (kA, 8/20 µs) | 15 kA |
| Rated load current IL (A) | 80 A |
| Continuous working current ICPV (µA) | < 20 µA |
| Maximum continuous voltage UCPV (V DC) | 1170 V DC |
| ISCPV short-circuit resistance (A) | 2000 A |
| Residual voltage Ures at In (kV) | ≤ 3.5 kV (at In) |
| Residual voltage Ures at 5 kA (kV) | ≤ 2.9 kV (at 5 kA) |
| Residual voltage Ures at 10 kA (kV) | ≤ 3.2 kV (at 10 kA) |
| Residual voltage Ures at 20 kA (kV) | ≤ 3.7 kV (at 20 kA) |
| Residual voltage Ures at 30 kA (kV) | ≤ 4.1 kV (at 30 kA) |
| Residual voltage Ures at 40 kA (kV) | ≤ 4.6 kV (at 40 kA) |
| Protective conductor current IPE DC (µA) | ≤ 20 µA DC |
| Protective conductor current IPE AC (µA) | ≤ 350 µA AC |
| Protection level Up (kV) | ≤ 3.5 kV |
| Power consumption in PC standby mode (mVA) | ≤ 25 mVA |
| Connection configuration | Y configuration |