Omvormer – SOLAX – X3-NEO-20K-LV – hybride – LV
| Fabrikant | |
|---|---|
| Nominaal vermogen | |
| Voeding | |
| Hybride apparaat | |
| Off-grid bedrijfsmodus | |
| MPPT | |
| Garantie | |
| Netto breedte | |
| Netto diepte | |
| Netto hoogte | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Typ III | |
| SPD Type I+II | |
| SPD – Vrije sleuf | |
| AFCI | |
| MPPT-spanningsbereik | |
| Maximale ingangsstroom per MPPT [A] | |
| Maximaal ingangsvermogen [W] | |
| Europese efficiëntie | |
| Gewicht | 51,2 kg |
| CN | 85044086 |
Incl. btw
Productdetails
| Fabrikant | |
|---|---|
| Nominaal vermogen | |
| Voeding | |
| Hybride apparaat | |
| Off-grid bedrijfsmodus | |
| MPPT | |
| Garantie | |
| Netto breedte | |
| Netto diepte | |
| Netto hoogte | |
| CAN | |
| CAN 2.0 | |
| RS485 | |
| SPD Type I | |
| SPD Type II | |
| SPD Typ III | |
| SPD Type I+II | |
| SPD – Vrije sleuf | |
| AFCI | |
| MPPT-spanningsbereik | |
| Maximale ingangsstroom per MPPT [A] | |
| Maximaal ingangsvermogen [W] | |
| Europese efficiëntie | |
| Gewicht | 51,2 kg |
| CN | 85044086 |
Hybride omvormers SolaX X3-NEO-20K-LV
De hybride omvormers SolaX X3-NEO-LV zijn driefasige laagspanningsoplossingen voor huishoudelijk gebruik. Ze bieden hoge prestaties, intelligent energiemanagement en geavanceerde beveiligingsfuncties, waardoor de zonne-energie optimaal wordt benut en de betrouwbaarheid van het systeem gewaarborgd is.
Belangrijkste kenmerken van de SolaX X3-NEO-LV:
- Globale MPP-tracking zorgt voor optimale energieopbrengst, en intelligent loadmanagement optimaliseert het energieverbruik.
- Uitzonderlijke betrouwbaarheid dankzij IP65-beschermingsklasse, batterij- temperatuurdetectie, overspanningsbeveiligingen (SPD) type II aan zowel de AC- als DC-zijde en optionele AFCI-bescherming.
- Tot 200% uitgangsvermogen van het EPS (Energy Provided System) gedurende 10 seconden en een UPS-overschakeltijd van minder dan 3 ms zorgen voor ononderbroken stroomvoorziening.
- Hoge efficiëntie dankzij maximaal 2 MPPT’s, 200% overdimensionering van het PV-ingangsvermogen en een lage startspanning.
- Flexibiliteit door parallelle aansluiting van maximaal 3 omvormers voor zowel netgekoppelde als off-grid werking, met microgrid- en generatorfuncties.
- Maximaal PV-vermogen tot 40 kWp en maximale PV-ingangsspanning tot 1000 V (afhankelijk van het model).
Voor wie is dit een goede keuze?
De SolaX X3-NEO-LV omvormers zijn een ideale keuze voor eigenaren van eengezinswoningen die op zoek zijn naar een efficiënt en betrouwbaar systeem voor het beheer van zonne-energie. Dankzij geavanceerde beveiligingsfuncties, de mogelijkheid tot parallelle werking en een breed spanningsbereik, zijn ze uitstekend geschikt voor uiteenlopende installaties en zorgen ze voor stabiele voeding en maximale benutting van de opgewekte energie.
| Parameter | X3-NEO-5K-LV | X3-NEO-8K-LV | X3-NEO-10K-LV | X3-NEO-12K-LV | X3-NEO-15K-LV | X3-NEO-20K-LV |
|---|---|---|---|---|---|---|
| PV-INGANGSPARAMETERS | ||||||
| Maximaal aanbevolen vermogen PV-panelen | 10 kWp | 16 kWp | 20 kWp | 24 kWp | 30 kWp | 40 kWp |
| Maximale PV-ingangsspanning | 1000 V | |||||
| Nominale PV-ingangsspanning | 640 V | |||||
| Werkspanningsbereik PV | 160~950 V | |||||
| Opstartspanning | 150 V | |||||
| Aantal MPPT / strings per MPPT | 2/(1/1) | 2/(1/1) | 2/(2/1) | 2/(2/2) | 2/(2/2) | 2/(2/2) |
| Maximale ingangsstroom per MPPT | 18 A / 18 A | 18 A / 18 A | 36 A / 18 A | 36 A / 36 A | 36 A / 36 A | 36 A / 36 A |
| Maximale kortsluitstroom per MPPT | 25 A / 25 A | 25 A / 25 A | 50 A / 25 A | 50 A / 50 A | 50 A / 50 A | 50 A / 50 A |
| AC-INGANG EN -UITGANG (NET) | ||||||
| Nominaal uitgangsvermogen | 5 kW | 8 kW | 10 kW | 12 kW | 15 kW | 20 kW |
| Nominale uitgangsstroom | 7.3 A @ 230 V | 11.6 A @ 230 V | 14.5 A @ 230 V | 17.4 A @ 230 V | 21.8 A @ 230 V | 29.0 A @ 230 V |
| Maximaal schijnbaar uitgangsvermogen | 5.5 KVA | 8.8 KVA | 11 KVA | 13.2 KVA | 16.5 KVA | 22.0 KVA |
| Maximale continue uitgangsstroom | 8.0 A @ 230 V | 12.8 A @ 230 V | 16.0 A @ 230 V | 19.2 A @ 230 V | 24.0 A @ 230 V | 31.9 A @ 230 V |
| Nominale AC-spanning | 3W/N/PE, 220/380 V
3W/N/PE, 230/400 V 3W/N/PE, 240/415 V |
|||||
| Maximaal schijnbaar AC-ingangsvermogen | 10 kVA | 16 KVA | 20 KVA | 24 KVA | 30 KVA | 30 KVA |
| Maximale AC-ingangsstroom | 14.5 A @ 230 V | 23.2 A @ 230 V | 29.0 A @ 230 V | 34.8 A @ 230 V | 43.5 A @ 230 V | 43.5 A @ 230 V |
| Maximale continue AC-doorvoer (net naar belasting) | 40 A | |||||
| Nominale AC-frequentie | 50 Hz / 60 Hz | |||||
| AC-frequentiebereik | 50 ± 5 Hz / 60 + 5 Hz | |||||
| Instelbaar vermogensfactorbereik | ~1 (0.8 traag tot 0.8 voortijdig) | |||||
| THDi (nominaal vermogen) | <3% | |||||
| BATTERIJ | ||||||
| Type batterij | LFP/loodzuur | |||||
| Batterijspanningsbereik | 40~60 V | |||||
| Maximale laad-/ontlaadstroom | 125 A / 125 A | 200 A / 200 A | 250 A / 250 A | 280 A / 280 A | 300 A / 300 A | 350 A / 350 A |
| EPS-UITGANG (OFF-GRID) (MET BATTERIJ) | ||||||
| Nominale EPS-uitgangsspanning, frequentie | 230 V/400 V, 50 Hz / 60 Hz | |||||
| Nominaal EPS-uitgangsvermogen | 5 KVA | 8 KVA | 10 KVA | 12 KVA | 15 KVA | 20 KVA |
| EPS piekuitgangsvermogen | 10 KVA | 16 KVA | 20 KVA | 24 KVA | 30 KVA | 40 KVA |
| Schakeltijd | <3 ms | |||||
| EFFICIËNTIE | ||||||
| Maximale efficiëntie | 97.6% | |||||
| Europese efficiëntie | 97.0% | |||||
| OVERIGE OMGEVINGSPARAMETERS | ||||||
| IP-classificatie | IP65 | |||||
| Werktemperatuurbereik | -25~60°C (>45°C met vermogensvermindering) | |||||
| Maximale bedrijfshoogte | 3000 m | |||||
| Relatieve luchtvochtigheid | 4~100% RV (zonder condensatie) | |||||
| Overspanningscategorie | Net: III, Batterij: II, PV: II | |||||
| ALGEMEEN | ||||||
| Afmetingen (b x h x d) | 520 x 705 x 258 mm | |||||
| Netto gewicht | 44.6 kg | 45.2 kg | ||||
| Koelingsconcept | Natuurlijke koeling | Intelligente luchtkoeling | ||||
| Communicatieinterfaces | RS485, CAN, USB, DI/DO | |||||
| Display | LCD | |||||
| Topologie | Niet-geïsoleerd aan de PV-zijde / HF aan de batterijzijde | |||||
| Certificaten | EN IEC 62109-1/-2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS, G98/G99 | |||||
| BESCHERMINGEN | ||||||
| Beveiligingen | Bescherming tegen overspanning/onderspanning, DC-isolatiebeveiliging, bescherming tegen omgekeerde DC-polariteit, netbewaking, DC-injectiebewaking, bewaking van terugstroom, detectie van lekstroom, beveiliging tegen oververhitting | |||||
| Methode voor actieve anti-islanding | Frequentieverschuiving | |||||
| Overspanningsbeveiliging | DC: Type II, AC: Type II | |||||
| Boogbeveiliging (AFCI) | Optioneel | |||||

